Ziege IgG anti-Alpaka IgG (VHH)-Cy5, MinX Bo
-
Übersicht
Artikelnummer 128-175-232 Wirtsspezies IgG-Form Spezies-Reaktivität Spezifität Isotyp Klonalität (Mono-/Polyklonal) Anwendung Durchflusszytometrie (Flow Cytometry), ELISA (Enzyme Linked Immunosorbent Assay), Immuncytochemie, Immunfluoreszenz, Immunhistochemie (Gefrierschnitte), Immunhistochemie (IHC), Immunhistochemie (Paraffingewebe)
Konjugation Maximale Anregung Maximale Emission Keine Kreuzreaktivität (MinX) mit Verdünnung Format 0,05% NaN3, 15 mg/ml BSA (IgG- und Protease-frei), 250 mM NaCl, affinitätsgereinigt durch antigenspezifische Affinitätschromatographie, in 10 mM PBS (pH 7,6), Lyophilisat
Zweckbestimmung Produktlinie / Thema Hersteller / Marke - Datenblätter und Downloads
-
Weitere Produktinformationen
Whole IgG antibodies are isolated as intact molecules from antisera by immunoaffinity chromatography. They have an Fc portion and two antigen binding Fab portions joined together by disulfide bonds and therefore they are divalent. The average molecular weight is reported to be about 160 kDa. The whole IgG form of antibodies is suitable for the majority of immunodetection procedures and is the most cost effective.Based on immunoelectrophoresis, Western blot and/or ELISA, the antibody reacts with the VHH domain of heavy chain (HC) alpaca IgG, subclasses 2 and 3, and with the VHH domain of llama IgG, subclasses 2 and 3. It also reacts with whole molecule alpaca and llama IgG1. No antibody was detected against non-immunoglobulin serum proteins. The antibody has been tested by ELISA and/or solid-phase adsorbed to ensure minimal cross-reaction with bovine serum proteins, but it may cross-react with immunoglobulins from other species.
These antibodies react primarily with the Fc region, and are not recommended for detection of VHH antibodies.
Conjugate
Cy5 conjugates are excited maximally at 650 nm and fluoresce maximally at 670 nm. They can be excited to about 98% of maximum with a krypton/argon laser (647 nm line) or to about 63% of maximum with a helium/neon laser (633 nm line). Cy5 can be used with a variety of other fluorophores for multiple labeling due to a wide separation of its emission from that of shorter wavelength-emitting fluorophores. However, we recommend Alexa Fluor 647 as the preferred far-red-fluorescing dye because it is brighter than Cy5 in aqueous mounting media. The reverse is true when mounting in non-polar, plastic mounting media, i.e. Cy5 is brighter than other far-red-fluorescing dyes, including Alexa Fluor 647 and DyLight 650.